Voltage multiplier arrangement for heavy load conditions in RF energy harvesting

Shailesh Singh Chouhan*, Kari Halonen

*Tämän työn vastaava kirjoittaja

Tutkimustuotos: Artikkeli kirjassa/konferenssijulkaisussaConference contributionScientificvertaisarvioitu

1 Sitaatiot (Scopus)

Abstrakti

In this work, a two-stage voltage multiplier (VM) is proposed where, an additional DC bias voltage has been derived directly from the input RF signal. As a result, the load driving capability of the proposed rectifier is higher for the heavy load conditions. The heavy load condition stands for the value of the load resistor lower than 30K Omega. The proposed architecture has been designed and fabricated in a standard 0.18 mu m CMOS technology. The measurements were done by emulating real load condition in terms of the resistance of values 1K Omega, 5K Omega, 10K Omega, 30K Omega and 100K Omega (light load). The measured power conversion efficiency (PCE) at ISM 433 MHz frequency is 43.4 % at -8 dBm for the resistive load of 5K Omega.

AlkuperäiskieliEnglanti
Otsikko2016 IEEE Nordic Circuits and Systems Conference (NORCAS)
KustantajaIEEE
Sivumäärä5
ISBN (elektroninen)978-1-5090-1095-0
DOI - pysyväislinkit
TilaJulkaistu - 2016
OKM-julkaisutyyppiA4 Artikkeli konferenssijulkaisuussa
TapahtumaIEEE Nordic Circuits and Systems Conference - Copenhagen, Tanska
Kesto: 1 marraskuuta 20162 marraskuuta 2016
Konferenssinumero: 2

Conference

ConferenceIEEE Nordic Circuits and Systems Conference
Lyhennettä NORCAS
MaaTanska
KaupunkiCopenhagen
Ajanjakso01/11/201602/11/2016

Siteeraa tätä