Test-retest evaluation of a notched-noise test using consumer-grade mobile audioequipment

Petteri Hyvärinen, Michal Fereczkowski, Ewen N. MacDonald

Tutkimustuotos: LehtiartikkeliArticleScientificvertaisarvioitu

7 Lataukset (Pure)

Abstrakti

Objective: The aim of this study was to investigate whether consumer-grade mobile audio equipment can be reliably used as a platform for the notched-noise test, including when the test is conducted outside the laboratory.

Design: Two studies were conducted: Study 1 was a notched-noise masking experiment with three different setups: in a psychoacoustic test booth with a standard laboratory PC; in a psychoacoustic test booth with a mobile device; and in a quiet office room with a mobile device. Study 2 employed the same task as Study 1, but compared circumaural headphones to insert earphones.

Study sample: Nine and ten young, normal-hearing participants completed studies 1 and 2, respectively.

Results: The test-retest accuracy of the notched-noise test on the mobile implementation did not differ from that for the laboratory setup. A possible effect of the earphone design was identified in Study 1, which was corroborated by Study 2, where test-retest variability was smallest when comparing results from experiments conducted using identical acoustic transducers.

Conclusions: Results and test-retest repeatability comparable to standard laboratory settings for the notched-noise test can be obtained with mobile equipment outside the laboratory.
AlkuperäiskieliEnglanti
Sivumäärä9
JulkaisuINTERNATIONAL JOURNAL OF AUDIOLOGY
DOI - pysyväislinkit
TilaSähköinen julkaisu (e-pub) ennen painettua julkistusta - 12 tammik. 2023
OKM-julkaisutyyppiA1 Julkaistu artikkeli, soviteltu

Sormenjälki

Sukella tutkimusaiheisiin 'Test-retest evaluation of a notched-noise test using consumer-grade mobile audioequipment'. Ne muodostavat yhdessä ainutlaatuisen sormenjäljen.

Siteeraa tätä