Recovering waste heat from flue gas of combined heat and power plants for district heating in China

Haichao Wang, Xiaozhou Wu, Lin Duanmu, Miika Rämä

Tutkimustuotos: Artikkeli kirjassa/konferenssijulkaisussaConference article in proceedingsScientificvertaisarvioitu

92 Lataukset (Pure)

Abstrakti

Currently, the flue gas heat recovery rate is very low in China. But flue gas can contain a large amount of waste heat according to the heat balance of the boiler. In the meantime, flue gas heat loss also dominates different kinds of heat losses for a boiler. Therefore, it is necessary to reduce the flue gas temperature and recover sensible and latent heat for district heating purpose. This paper discusses the application mode of a flue gas scrubber for a combined heat and power (CHP) plant, calculate the flue gas recovery rate using absorption heat pumps and analyse the feasibility for a real case study in China. The results show that the maximum heat recovery rate is about 8% if the flue gas can be cooled down to 30°C, and the payback time for the flue gas scrubber is around 5 years.
AlkuperäiskieliEnglanti
OtsikkoProceedings Roomvent & Ventilation 2018
KustantajaSIY Sisäilmatieto Oy
Sivumäärä6
ISBN (elektroninen)978-952-5236-48-4
TilaJulkaistu - 2018
OKM-julkaisutyyppiA4 Artikkeli konferenssijulkaisussa
TapahtumaInternational Conference on Air Distribution in Rooms
- Espoo, Suomi
Kesto: 2 kesäk. 20185 kesäk. 2018

Conference

ConferenceInternational Conference on Air Distribution in Rooms
LyhennettäROOMVENT
Maa/AlueSuomi
KaupunkiEspoo
Ajanjakso02/06/201805/06/2018

Sormenjälki

Sukella tutkimusaiheisiin 'Recovering waste heat from flue gas of combined heat and power plants for district heating in China'. Ne muodostavat yhdessä ainutlaatuisen sormenjäljen.

Siteeraa tätä