QTR-FRET: Efficient background reduction technology in time-resolved förster resonance energy transfer assays

  • Markku Syrjänpää
  • , Emmiliisa Vuorinen
  • , Sakari Kulmala
  • , Qi Wang
  • , Harri Härmä
  • , Kari Kopra*
  • *Tämän työn vastaava kirjoittaja
  • University of Turku

Tutkimustuotos: Lehtiartikkeli › Article › Scientific › vertaisarvioitu

7 Sitaatiot (Scopus)

Abstrakti

A novel homogeneous assay system QTR-FRET (Quencher modulated Time-Resolved Förster Resonance Energy Transfer) combining quenching resonance energy transfer (QRET) and time-resolved Förster resonance energy transfer (TR-FRET) was developed to reduce background signal in the conventional energy transfer applications. The TR-FRET functionality is often limited by the lanthanide donor background signal leading to the use of low donor concentration. QTR-FRET reduces this background by introducing soluble quencher molecule, and in this work the concept functionality was proven and compared to previously introduced QRET and TR-FRET technologies. Comparison was performed with three different Eu3+-chelates exhibiting different luminescent lifetime and stability. The side-by-side comparison of the three signaling systems and Eu3+-chelates was demonstrated in a model assay with Eu3+-chelate conjugated biotin and streptavidin (SA) or Cy5-SA conjugate. Comparison of the methodologies showed increased signal-to-background ratios when comparing QTR-FRET to TR-FRET, especially at high Eu3+-biotin concentrations. Quenching the non-bound Eu3+-biotin improved the assay performance, which suggests that an improved assay performance can be attained with the QTR-FRET method. QTR-FRET is expected to be especially useful for Eu3+-labeled ligands with low affinity or assays requiring high Eu3+-ligand concentration. The QTR-FRET indicated potential for multi-analyte approaches separately utilizing the direct QRET-type Eu3+-chelate signal and energy transfer signal readout in a single-well. This potential was hypothesized with Avi-KRAS nucleotide exchange assay as a second biologically relevant model system.

AlkuperäiskieliEnglanti
Sivut93-101
Sivumäärä9
JulkaisuAnalytica Chimica Acta
Vuosikerta1092
DOI - pysyväislinkit
TilaJulkaistu - 19 syysk. 2019
OKM-julkaisutyyppiA1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä

Rahoitus

This work is supported by the Academy of Finland, Finland (Project IDs: 296225 and 296093 ) and Moikoisten Syöväntutkimussäätiö, Finland . We thank Jonas Kapp from University of Zurich, Switzerland and Dr. William Gillette from Leidos Biomedical Research, Inc., Frederick National Laboratory for Cancer Research, MD, USA for providing us the Avi-KRAS and SOS cat proteins. Appendix A

Sormenjälki

Sukella tutkimusaiheisiin 'QTR-FRET: Efficient background reduction technology in time-resolved förster resonance energy transfer assays'. Ne muodostavat yhdessä ainutlaatuisen sormenjäljen.

Siteeraa tätä