Ventilation, air filtration and disinfection have been found to be the main engineering measures to control the airborne respiratory infection transmission in shared indoor spaces. Wells-Riley model modifications allow to calculate the infection risk probability, but gaps in viral load data, risk control methods and dealing with incomplete mixing have resulted in ventilation recommendations falling short to consider activity and room specific viral loads and actual air distribution systems deviating from fully mixing. In this study a new infection risk-based ventilation design method operating with space category specific target ventilation rates and point source ventilation effectiveness is proposed. The method introduces the following novelties: i) explicit target ventilation rate equations depending on number of occupants and room volume derived for selected room categories ii) implementation of pre-symptomatic period infection risk control iii) point source ventilation effectiveness application to calculate the design ventilation rate for actual air distribution system iv) ventilation effectiveness measurement method with at least two point source locations developed and tested with laboratory and field measurements. Results show that in classrooms and offices existing Category I ventilation is enough in many cases, but higher ventilation is needed in meeting rooms, restaurants, and gyms where also occupancy reduction and advanced air distribution can be considered for feasible ventilation design.

AlkuperäiskieliEnglanti
Artikkeli113386
Sivumäärä13
JulkaisuEnergy and Buildings
Vuosikerta296
DOI - pysyväislinkit
TilaJulkaistu - 1 lokak. 2023
OKM-julkaisutyyppiA1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä

Rahoitus

Estonian Centre of Excellence in Zero Energy and Resource Efficient Smart Buildings and Districts, ZEBE (grant 2014-2020.4.01.15-0016) funded by the European Regional Development Fund, EU Horizon 2020 SmartLivingEPC project (Grant Agreement number: 101069639) and Finnish Government's analysis, assessment, and research project ILMIRA, have supported this research. Nordic Ventilation Group and REHVA Technology and Research Committee COVID-19 Task Force are greatly acknowledged for support to develop this ventilation design method. Estonian Centre of Excellence in Zero Energy and Resource Efficient Smart Buildings and Districts, ZEBE (grant 2014-2020.4.01.15-0016) funded by the European Regional Development Fund, EU Horizon 2020 SmartLivingEPC project (Grant Agreement number: 101069639) and Finnish Government's analysis, assessment, and research project ILMIRA, have supported this research. Nordic Ventilation Group and REHVA Technology and Research Committee COVID-19 Task Force are greatly acknowledged for support to develop this ventilation design method.

YK:n kestävän kehityksen tavoitteet

Tämä tuotos edistää seuraavia kestävän kehityksen tavoitteita:

  1. SDG 3 – Hyvä terveys ja hyvinvointi
    SDG 3 – Hyvä terveys ja hyvinvointi

Sormenjälki

Sukella tutkimusaiheisiin 'Post-COVID ventilation design : Infection risk-based target ventilation rates and point source ventilation effectiveness'. Ne muodostavat yhdessä ainutlaatuisen sormenjäljen.

Siteeraa tätä