A. Mennella*, R.C. Butler, A. Curto, F. Cuttaia, R.J. Davis, J. Dick, M. Frailis, S. Galeotta, A. Gregorio, H. Kurki-Suonio, C.R. Lawrence, S. Leach, J.P. Leahy, S. Lowe, D. Maino, N. Mandolesi, M. Maris, E. Martínez-González, P.R. Meinhold, G. MorganteD. Pearson, F. Perrotta, G. Polenta, T. Poutanen, M. Sandri, M.D. Seiffert, A.-S. Suur-Uski, D. Tavagnacco, L. Terenzi, M. Tomasi, J. Valiviita, F. Villa, R. Watson, A. Wilkinson, A. Zacchei, A. Zonca, B. Aja, E. Artal, C. Baccigalupi, A.J. Banday, R.B. Barreiro, J.G. Bartlett, N. Bartolo, P. Battaglia, K. Bennett, A. Bonaldi, L. Bonavera, J. Borrill, F.R. Bouchet, C. Burigana, P. Cabella, B. Cappellini, X. Chen, L. Colombo, M. Cruz, L. Danese, O. "D'Arcangelo", R.D. Davies, G. de Gasperis, A. de Rosa, G. de Zotti, C. Dickinson, J.M. Diego, S. Donzelli, G. Efstathiou, T.A. Enßlin, H.K. Eriksen, M.C. Falvella, F. Finelli, S. Foley, C. Franceschet, E. Franceschi, T.C. Gaier, R.T. Génova-Santos, D. George, F. Gómez, J. González-Nuevo, K.M. Górski, A. Gruppuso, F.K. Hansen, D. Herranz, J.M. Herreros, R.J. Hoyland, N. Hughes, J. Jewell, P. Jukkala, M. Juvela, P. Kangaslahti, E. Keihänen, R. Keskitalo, V.-H. Kilpia, T.S. Kisner, J. Knoche, L. Knox, M. Laaninen, A. Lähteenmäki, J.-M. Lamarre, R. Leonardi, J. León-Tavares, P. Leutenegger, P.B. Lilje, M. López-Caniego, P.M. Lubin, M. Malaspina, D. Marinucci, M. Massardi, S. Matarrese, F. Matthai, A. Melchiorri, L. Mendes, M. Miccolis, M. Migliaccio, S. Mitra, A. Moss, P. Natoli, R. Nesti, H.U. Nørgaard-Nielsen, L. Pagano, R. Paladini, D. Paoletti, B. Partridge, F. Pasian, V. Pettorino, D. Pietrobon, M. Pospieszalski, G. Prézeau, M. Prina, P. Procopio, J.-L. Puget, C. Quercellini, J.P. Rachen, R. Rebolo, M. Reinecke, S. Ricciardi, G. Robbers, G. Rocha, N. Roddis, J.A. Rubino-Martín, M. Savelainen, D. Scott, R. Silvestri, A. Simonetto, P. Sjoman, G.F. Smoot, C. Sozzi, L. Stringhetti, J.A. Tauber, G. Tofani, L. Toffolatti, J. Tuovinen, M. Türler, G. Umana, L. Valenziano, J. Varis, P. Vielva, N. Vittorio, L.A. Wade, C. Watson, S.D.M. White, F. Winder

*Tämän työn vastaava kirjoittaja

Tutkimustuotos: LehtiartikkeliArticleScientificvertaisarvioitu

125 Sitaatiot (Scopus)

Abstrakti

The scientific performance of the Planck Low Frequency Instrument (LFI) after one year of in-orbit operation is presented. We describe the main optical parameters and discuss photometric calibration, white noise sensitivity, and noise properties. A preliminary evaluation of the impact of the main systematic effects is presented. For each of the performance parameters, we outline the methods used to obtain them from the flight data and provide a comparison with pre-launch ground assessments, which are essentially confirmed in flight.
AlkuperäiskieliEnglanti
ArtikkeliA3
Sivumäärä29
JulkaisuAstronomy and Astrophysics
Vuosikerta536
DOI - pysyväislinkit
TilaJulkaistu - jouluk. 2011
OKM-julkaisutyyppiA1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä

Sormenjälki

Sukella tutkimusaiheisiin 'Planck early results: III. First assessment of the Low Frequency Instrument in-flight performance'. Ne muodostavat yhdessä ainutlaatuisen sormenjäljen.

Siteeraa tätä