Abstrakti
This paper presents the experimental study of induction generator broken rotor bars diagnostics. As induction generators are often used in renewable energy applications, such as wind and hydro power plants where they are also equipped with frequency converters, diagnostics of such machines is becoming more important. Tests are performed with an induction machine with a healthy rotor and a rotor with three broken bars, supplied through a frequency converter. Park's vector approach is used as an analyzing tool to detect the broken rotor bars. Park's vector pattern using stator current and voltage is investigated. Results of the tests and discussion of the results are presented. The necessity for further study is pointed out.
Alkuperäiskieli | Englanti |
---|---|
Otsikko | Proceedings of the 13th International Scientific Conference Electric Power Engineering 2012, EPE 2012 |
Kustantaja | Brno University of Technology |
Sivut | 985-988 |
Sivumäärä | 4 |
Vuosikerta | 2 |
Tila | Julkaistu - 2012 |
OKM-julkaisutyyppi | A4 Artikkeli konferenssijulkaisuussa |
Tapahtuma | International Scientific Conference Electric Power Engineering - Brno, Tshekki Kesto: 23 toukokuuta 2012 → 25 toukokuuta 2012 Konferenssinumero: 13 |
Conference
Conference | International Scientific Conference Electric Power Engineering |
---|---|
Lyhennettä | EPE |
Maa | Tshekki |
Kaupunki | Brno |
Ajanjakso | 23/05/2012 → 25/05/2012 |