Observer-based state-space current control for a three-phase grid-connected converter equipped with an LCL filter

Jarno Kukkola, Marko Hinkkanen

Tutkimustuotos: LehtiartikkeliArticleScientificvertaisarvioitu

99 Sitaatiot (Scopus)
375 Lataukset (Pure)

Abstrakti

This paper presents a state-space current control method for active damping of the resonance frequency of the LCL filter and setting the dominant dynamics of the converter current through direct pole placement. A state observer is used, where upon additional sensors are not needed in comparison with the conventional L filter design. The relationship between the system delay and instability caused by the resonance phenomenon is considered. Nyquist diagrams are used to examine the parameter sensitivity of the proposed method. The method is validated with simulations and experiments.
AlkuperäiskieliEnglanti
Sivut2700-2709
JulkaisuIEEE Transactions on Industry Applications
Vuosikerta50
Numero4
DOI - pysyväislinkit
TilaJulkaistu - 15 heinäk. 2014
OKM-julkaisutyyppiA1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä

Tutkimusalat

  • delay
  • LCL filter
  • Nyquist diagram
  • parameter sensitivity
  • phase-lead compensator
  • state-space current control

Sormenjälki

Sukella tutkimusaiheisiin 'Observer-based state-space current control for a three-phase grid-connected converter equipped with an LCL filter'. Ne muodostavat yhdessä ainutlaatuisen sormenjäljen.

Siteeraa tätä