Internal moisture excess of residential buildings in Finland

  • Juha Vinha
  • , Mikko Salminen
  • , Kati Salminen
  • , Targo Kalamees
  • , Jarek Kurnitski
  • , Mihkel Kiviste*
  • *Tämän työn vastaava kirjoittaja

Tutkimustuotos: LehtiartikkeliArticleScientificvertaisarvioitu

27 Sitaatiot (Scopus)

Abstrakti

In Finland, the indoor air conditions of 171 single-family buildings and 49 apartments in multi-family buildings have been studied in large research projects in collaboration with Tampere University of Technology and Helsinki University of Technology. This article deals with the results of moisture excess studied in these single-family buildings and apartments. Continuous field measurements up to 28 months enable to include two consecutive heating seasons in the analysis of the internal moisture excess. The higher 10% critical level during the cold period (Te ≤ 5°C) was between 3.4 and 4.9 g/ m3 in Finnish heavyweight and lightweight single-family buildings and between 2.4 and 3.6 g/m3 in apartments of multi-family buildings. During the warm period (Te ≥15°C), the corresponding values were between 0.3 and 2.6 g/m3 for single-family buildings and 0.5 and 1.5 g/m3 for apartments. The number of occupants and the airtightness of different groups of external wall did not have influence on the average values of moisture excess. Slightly better ventilation air change rates were measured in apartments of multi-family buildings, where also the air change rates from supply–exhaust ventilation systems generally fulfilled the Finnish guideline value. The design values of moisture classes in EN ISO 13788:2012 were found difficult to apply for Finnish residential buildings. The upper limit value of humidity class 2 of EN ISO 13788:2012 is suitable for apartments in Finnish multi-family buildings, but too low for Finnish lightweight and heavyweight single-family buildings. Applying the design values of Finnish guidelines would be justified for the studied buildings almost at the full range of outdoor temperatures.

AlkuperäiskieliEnglanti
Sivut239-258
Sivumäärä20
JulkaisuJournal of Building Physics
Vuosikerta42
Numero3
DOI - pysyväislinkit
TilaJulkaistu - 1 tammik. 2018
OKM-julkaisutyyppiA1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä

Rahoitus

This research has been done in connection with the national research project ‘Air tightness, indoor climate and energy efficiency of residential buildings’ by the Laboratory of Civil Engineering at TUT and HVAC Laboratory at HUT. The authors are grateful to all financiers and assisting people in this project. The author(s) disclosed receipt of the following financial support for the research, authorship, and/or publication of this article: This project was financed by TEKES (Finnish Funding Agency for Technology and Innovation), Finnish companies and associations.

YK:n kestävän kehityksen tavoitteet

Tämä tuotos edistää seuraavia kestävän kehityksen tavoitteita:

  1. SDG 7 – Edullinen ja puhdas energia
    SDG 7 – Edullinen ja puhdas energia
  2. SDG 9 – Teollisuus, innovaatiot ja infrastruktuuri
    SDG 9 – Teollisuus, innovaatiot ja infrastruktuuri
  3. SDG 12 – Vastuullinen kulutus ja tuotanto
    SDG 12 – Vastuullinen kulutus ja tuotanto

Sormenjälki

Sukella tutkimusaiheisiin 'Internal moisture excess of residential buildings in Finland'. Ne muodostavat yhdessä ainutlaatuisen sormenjäljen.

Siteeraa tätä