INTERGRANULAR CORROSION TESTING OF NICKEL-BASE ALLOYS.

T. Kekkonen*, P. Aaltonen, Hannu Hänninen

*Tämän työn vastaava kirjoittaja

Tutkimustuotos: LehtiartikkeliArticleScientificvertaisarvioitu

3 Sitaatiot (Scopus)

Abstrakti

An electrochemical test method based on the Electrochemical Potentiokinetic Reactivation (EPR) test has been employed to quantify the degree of sensitization in Inconel 600, Inconel X-750 and Sanicro 31 H. Several standardized test methods have also been used and the results are compared. The electrochemical reactivation test is a useful tool for comparing the degree of sensitization between various sensitized conditions; however, determination of an exact quantitative value is difficult because of many variables.

AlkuperäiskieliEnglanti
Sivut243-251
Sivumäärä9
JulkaisuScandinavian Journal of Metallurgy
Vuosikerta14
Numero5
TilaJulkaistu - 1985
OKM-julkaisutyyppiA1 Julkaistu artikkeli, soviteltu

Sormenjälki

Sukella tutkimusaiheisiin 'INTERGRANULAR CORROSION TESTING OF NICKEL-BASE ALLOYS.'. Ne muodostavat yhdessä ainutlaatuisen sormenjäljen.

Siteeraa tätä