Increase of Air Content of Concrete After Mixing

Tutkimustuotos: Artikkeli kirjassa/konferenssijulkaisussaKonferenssiesitysScientificvertaisarvioitu

Abstrakti

Lately, elevated air contents up to 15% have been observed in fresh air-entrained concrete in Finland. To investigate the air content elevation, Robust Air project was established at Aalto University Department of Civil Engineering. Target of the project was to secure the stability of the protective pore system. The project was financed by Finnish Transportation Agency, concrete industry and admixture suppliers. The main part of the research was made in the laboratory tests which were divided into two parts. In the first part, the concrete properties were altered and the same admixtures were used. In the second part, the concrete properties were kept constant and the admixtures were altered. The main interest of the laboratory tests was to analyse the air content of concrete as function of time after mixing. The measurements were carried out immediately after mixing, 30, 60 and 75 min after mixing. In addition to the laboratory tests, factory tests the Finnish concrete industry made tests in which the air content of concrete was measured after normal mixing time but also after 6 min mixing time. Based on the experiments, it was observed that the mixing process of the air-entrained concrete is not necessarily effective enough. It is possible that only part of the entrained air is formed during the mixing process and there is a risk for elevated air content when the concrete is mixed in the concrete truck during the transportation and unloading. The phenomenon was explained by Air content potential. Each concrete has an Air content potential (maximum air content) which depends on the admixture combination, concrete composition and the consistency of concrete. Recommendations are given to minimize the risk for elevated air contents. The recommendations include development actions related to admixtures, concrete mixers, quality control systems and to requirements of freeze-thaw resistance concrete. The concrete producers need to take the phenomenon better into account in the concrete manufacturing process.

AlkuperäiskieliEnglanti
Sivumäärä12
TilaJulkaistu - 2018
OKM-julkaisutyyppiEi oikeutettu
TapahtumaEuropean Ready Mixed Concrete Organization Congress - Oslo, Norja
Kesto: 7 kesäkuuta 20188 kesäkuuta 2018

Conference

ConferenceEuropean Ready Mixed Concrete Organization Congress
LyhennettäERMCO
MaaNorja
KaupunkiOslo
Ajanjakso07/06/201808/06/2018

Sormenjälki Sukella tutkimusaiheisiin 'Increase of Air Content of Concrete After Mixing'. Ne muodostavat yhdessä ainutlaatuisen sormenjäljen.

  • Siteeraa tätä

    Al-Neshawy, F., & Punkki, J. (2018). Increase of Air Content of Concrete After Mixing. Julkaisun esittämispaikka: European Ready Mixed Concrete Organization Congress, Oslo, Norja.