Projekteja vuodessa
Abstrakti
Reported indoor air quality (IAQ) complaints are common even in relatively new or renovated school buildings in Finland. However, detecting the causes for complaints with commonly used indoor air measurements is difficult. This study presents data on perceived and measured IAQ in six comprehensive school buildings in Finland. The aim of this study was to discover the possible differences of perceived and measured IAQ between schools with reported IAQ complaints and schools without reported IAQ complaints. The initial categorisation of schools with (‘problematic schools’) and without (‘comparison schools’) complaints was ensured via a validated indoor climate survey and a recently developed online questionnaire, which were completed by 186 teachers and 1268 students from the six schools. IAQ measurements of physical parameters, gaseous pollutants, particulate matter and bioaerosols were conducted in four problematic school buildings (26 classrooms) and two comparison school buildings (12 classrooms). Using air sampling as well as exhaust air filters and classroom settled dust to detect the presence of elevated concentrations of airborne cultivable microbes and pathogenic, toxigenic and mycoparasitic Trichoderma strains were the most indicative methods in distinguishing problematic schools from comparison schools. Other IAQ-related measurements did not detect clear differences between problematic and comparison schools, as the concentration levels were very low. The results indicate that the complaints reported by occupants could have been related to excess moisture or mould problems that had not been found or repaired. Ventilation pressure condition investigations and simultaneous exhaust and supply air filter dust culture should be addressed precisely in future studies.
| Alkuperäiskieli | Englanti |
|---|---|
| Artikkeli | 105781 |
| Sivumäärä | 14 |
| Julkaisu | Environment International |
| Vuosikerta | 141 |
| DOI - pysyväislinkit | |
| Tila | Julkaistu - elok. 2020 |
| OKM-julkaisutyyppi | A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä |
Rahoitus
The authors warmly acknowledge the Finnish Work Environment Fund (grant for EURA 115376), Business Finland (grant for Indoor air police—detection and prevention of IAQ problems 4098/31/2015) and the Academy of Finland (grant for TOXICPM 289161) for funding this research. The participation of the City of Helsinki, City of Vantaa and all studied schools is greatly appreciated, as well as the Finnish Institute of Occupational Health for the work in analysing the questionnaires and chemical samples. Doctoral candidates Tuomas Alapieti, Emmanuelle Castagnoli, Sander Toomla and D.Sc. Kaiser Ahmed are highly acknowledged for their invaluable contributions in conducting the investigations. László Kredics is grantee of the János Bolyai Research Scholarship (Hungarian Academy of Sciences) and the Bolyai Plus Scholarship (New National Excellence Programme, Hungary). This work was supported by the Finnish Work Environment Fund [grant number 115376 ]; Business Finland [grant number 4098/31/2015 ]; and the Academy of Finland [grant number 289161 ].
Sormenjälki
Sukella tutkimusaiheisiin 'Exposure to indoor air contaminants in school buildings with and without reported indoor air quality problems'. Ne muodostavat yhdessä ainutlaatuisen sormenjäljen.Projektit
- 1 Päättynyt
-
Toksiinin kulkeutumistavat kosteusvaurioituneista rakenteista sisäilmaan
Kurnitski, J. (Vastuullinen johtaja), Nguyen, N. (Projektin jäsen), Piironen, J. (Projektin jäsen), Alapieti, T. (Projektin jäsen), Järvi, K. (Projektin jäsen), Castagnoli, E. (Projektin jäsen), Vornanen, C. (Projektin jäsen), Salonen, H. (Projektin jäsen), Mikkola, R. (Projektin jäsen), Ahmed, K. (Projektin jäsen), Taebnia, M. (Projektin jäsen) & Andersson, A. (Projektin jäsen)
01/09/2015 → 31/08/2019
Projekti: Academy of Finland: Other research funding