Experiments and Numerical Simulations of Pressure Effects in Apartment Fires

Tutkimustuotos: Lehtiartikkeli

Tutkijat

Organisaatiot

Kuvaus

The fire induced pressure and its influence on ventilation flows within a compartment have not been studied in detail previously.In this research work, we have investigated the development of gas pressure and the resulting flows in compartment fires first experimentally, by burning a series of heptane pool and polyurethane mattress fires inside a real, 58.6 m^2 by 2.57 m high, apartment and then by carrying out numerical simulations of the experiments with the FDS code. The experiments were conducted with three different ventilation duct configurations to simulate three different airtightness conditions. The peak heat release rates were less than 1 MW and the burning times were about 180 s.
The experimental results indicate that the gas pressure in relatively closed apartment can become high enough to revert the flows of the ventilation system, prevent escape through inwards-opening doors, and even break some structures. The peak gas temperatures under the ceiling of the burn room were about 300 C. The pool fires remained well-ventilated. The pressure ranges encountered in the experiments were between 100 Pa to 1650 Pa and the pressure occured within 50 s of ignition. We also report the FDS validation for this type of simulations and discuss the process of modelling the ventilation system and leakages.

Yksityiskohdat

AlkuperäiskieliEnglanti
Sivut1353-1377
Sivumäärä25
JulkaisuFire Technology
Vuosikerta53
Numero3
Varhainen verkossa julkaisun päivämäärä30 joulukuuta 2016
TilaJulkaistu - toukokuuta 2017
OKM-julkaisutyyppiA1 Julkaistu artikkeli, soviteltu

Lataa tilasto

Ei tietoja saatavilla

ID: 10186755