Experimental study on airflow characteristics with asymmetrical heat load distribution and low-momentum diffuse ceiling ventilation

  • Turku University of Applied Sciences

Tutkimustuotos: Lehtiartikkeli › Article › Scientific › vertaisarvioitu

28 Sitaatiot (Scopus)
217 Lataukset (Pure)

Abstrakti

Airflow characteristics were studied with asymmetrically distributed heat load and diffuse ceiling ventilation. The heat load was gradually increased from 40 to 80 W/floor-m2 while the target temperature of exhaust air was kept at 26 ± 0.5 °C. Experiments were carried out in a test room by conducting measurements with omnidirectional anemometers, data loggers and marker-smoke visualizations. The heat load consisted of two opposite workstations next to heated window panels in the perimeter area. The other side of the room was an open area describing a corridor zone. The workstation had a seated test dummy with laptop and monitor. The results indicate that asymmetrical heat load distribution creates a large-scale circulating airflow pattern from the heat sources to the opposite side of the room. Furthermore, the mean air speed and the airflow fluctuation increased with heat load and supply airflow rate. Consequently, also the turbulent kinetic energy and the turbulence dissipation increased. However, heat load had only a small effect on the turbulence intensity and the fluctuation energy ratio. Therefore, draught rate increased significantly with mean air speed. The observed results agree mainly with the symmetrical heat load results otherwise, except for the systematic large-scale circulation that was not found in the symmetrical test case. The maximum draught rate was 18–21% indicating the category B-C of thermal environment defined by the European Standard EN ISO 7730:2005. The thermal conditions at the investigated heat loads of 40–80 W/floor-m2 were not able to fulfill the category A.
AlkuperäiskieliEnglanti
Sivut168-180
Sivumäärä13
JulkaisuBuilding and Environment
Vuosikerta134
DOI - pysyväislinkit
TilaJulkaistu - 15 huhtik. 2018
OKM-julkaisutyyppiA1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä

YK:n kestävän kehityksen tavoitteet

Tämä tuotos edistää seuraavia kestävän kehityksen tavoitteita:

  1. SDG 7 – Edullinen ja puhdas energia
    SDG 7 – Edullinen ja puhdas energia
  2. SDG 9 – Teollisuus, innovaatiot ja infrastruktuuri
    SDG 9 – Teollisuus, innovaatiot ja infrastruktuuri
  3. SDG 12 – Vastuullinen kulutus ja tuotanto
    SDG 12 – Vastuullinen kulutus ja tuotanto

Sormenjälki

Sukella tutkimusaiheisiin 'Experimental study on airflow characteristics with asymmetrical heat load distribution and low-momentum diffuse ceiling ventilation'. Ne muodostavat yhdessä ainutlaatuisen sormenjäljen.

Siteeraa tätä