TY - JOUR
T1 - Effects of Packer Locations on Downhole Electric Heater Performance: Experimental Test and Economic Analysis
AU - Guo, Wei
AU - Wang, Zhendong
AU - Sun, Youhong
AU - Lu-Tervola, Xiaoshu
AU - Wang, Yuan
AU - Deng, Sunhua
AU - Li, Qiang
PY - 2020/1/13
Y1 - 2020/1/13
N2 - A downhole electric heater, which reduces heat loss along a heat insulation pipe, is a key apparatus used to ignite oil shale underground. Downhole heaters working together with packers can improve the heating efficiency of high-temperature gases, while different packer locations will directly affect the external air temperature of the heater shell and, subsequently, the performance and total cost of the downhole heaters. A device was developed to simulate the external conditions of heater shells at different packer locations. Then, the effects of external air temperature on the performance of a downhole heater with pitches of 50, 160, and 210 mm were experimentally studied. In the test, results indicated that the heater with a packer at its outlet had an accelerated heating rate in the initial stage and decreased temperature in the final stage. Additionally, the lowest heating rod surface temperature and highest comprehensive performance were achieved with minimal irreversible loss and lower total cost when using a downhole electric heater with a packer set at its outlet. In addition, the downhole electric heater with a helical pitch of 50 mm and a packer at its outlet was more effective than other schemes in the high Reynolds number region. These findings are beneficial for shortening the oil production time in oil shale in situ pyrolysis and heavy oil thermal recovery.
AB - A downhole electric heater, which reduces heat loss along a heat insulation pipe, is a key apparatus used to ignite oil shale underground. Downhole heaters working together with packers can improve the heating efficiency of high-temperature gases, while different packer locations will directly affect the external air temperature of the heater shell and, subsequently, the performance and total cost of the downhole heaters. A device was developed to simulate the external conditions of heater shells at different packer locations. Then, the effects of external air temperature on the performance of a downhole heater with pitches of 50, 160, and 210 mm were experimentally studied. In the test, results indicated that the heater with a packer at its outlet had an accelerated heating rate in the initial stage and decreased temperature in the final stage. Additionally, the lowest heating rod surface temperature and highest comprehensive performance were achieved with minimal irreversible loss and lower total cost when using a downhole electric heater with a packer set at its outlet. In addition, the downhole electric heater with a helical pitch of 50 mm and a packer at its outlet was more effective than other schemes in the high Reynolds number region. These findings are beneficial for shortening the oil production time in oil shale in situ pyrolysis and heavy oil thermal recovery.
KW - oil shale
KW - in situ pyrolysis
KW - packer
KW - downhole electric heater
KW - economic analysis
UR - http://www.scopus.com/inward/record.url?scp=85077796358&partnerID=8YFLogxK
U2 - 10.3390/en13020377
DO - 10.3390/en13020377
M3 - Article
SN - 1996-1073
VL - 13
JO - Energies
JF - Energies
IS - 2
M1 - 377
ER -