Effect of plasma response on the fast ion losses due to ELM control coils in ITER

Tutkimustuotos: Lehtiartikkelivertaisarvioitu

Tutkijat

Organisaatiot

  • Tokamak Energy Ltd
  • Fusion for Energy
  • Chalmers University of Technology
  • Princeton University
  • JET

Kuvaus

Mitigating edge localized modes (ELMs) with resonant magnetic perturbations (RMPs) can increase energetic particle losses and resulting wall loads, which have previously been studied in the vacuum approximation. This paper presents recent results of fusion alpha and NBI ion losses in the ITER baseline scenario modelled with the Monte Carlo orbit following code ASCOT in a realistic magnetic field including the effect of the plasma response. The response was found to reduce alpha particle losses but increase NBI losses, with up to 4.2% of the injected power being lost. Additionally, some of the load in the divertor was found to be shifted away from the target plates toward the divertor dome.

Yksityiskohdat

AlkuperäiskieliEnglanti
Artikkeli046014
Sivut1-7
JulkaisuNuclear Fusion
Vuosikerta56
Numero4
TilaJulkaistu - 23 maaliskuuta 2016
OKM-julkaisutyyppiA1 Julkaistu artikkeli, soviteltu

ID: 3231420