Effect of Infector’s location and occupants’ activity level on airborne spread in a gym – an experimental and CFD study

Tutkimustuotos: LehtiartikkeliConference articleScientificvertaisarvioitu

1 Lataukset (Pure)

Abstrakti

The airborne spread of pathogens in indoor environments, such as gyms, has gained significant importance due to its potential role in the transmission of infectious diseases. The presented study was performed in a gym setting equipped with a mixing ventilation system, spanning a floor area of 173.5 m2 (17.5m x 9.9m). Using a combination of computational simulations and field measurements, the investigation assessed the effect of source location with respect to exhaust on the distribution of airborne particles. This study also encompassed the effect of pathogens spread on two different levels of physical activities i.e., sedentary, and heavy. The findings were quantified using the local air quality index. The research revealed that when the sedentary contaminant source was positioned near the exhaust, there was a substantial reduction in the spread of contaminants, leading to higher values of the local air quality index, ranging between 0.1 – 5.5 as compared to the value of 0.1-1.2 when the source was farther away from the exhaust. It means when the source is near the return opening, the contaminants could be exhausted before they are fully mixed in the gym environment. For heavy physical activity, when there were increased breathing rates and higher heat gains associated with the occupants, the influence of the source’s location still exists, but there was a significant reduction in the local air quality index as compared to sedentary activity as the value was between 0.1 - 3.2 for the infector near the exhaust. The investigation emphasizes the need to account for physical activity levels when designing gym ventilation systems due to significantly higher contaminant spread during heavy activity. Additionally, the investigation has revealed the effect of injector location, particularly with respect to exhaust grille.
AlkuperäiskieliEnglanti
Artikkeli07005
Sivumäärä5
JulkaisuE3S Web of Conferences
Vuosikerta672
DOI - pysyväislinkit
TilaJulkaistu - 2025
OKM-julkaisutyyppiA4 Artikkeli konferenssijulkaisussa
TapahtumaInternational Conference on Air Distribution in Rooms - Stockholm, Ruotsi
Kesto: 22 huhtik. 202425 huhtik. 2024
http://roomvent2024.com

Rahoitus

The authors wish to acknowledge the Finnish Prime Minister’s Office (VN TEAS 457/2023) for financial support of the ILMIRA project. The authors would also like to thank Halton Oy for providing product data to help with the modeling of the swirl diffusers.

Sormenjälki

Sukella tutkimusaiheisiin 'Effect of Infector’s location and occupants’ activity level on airborne spread in a gym – an experimental and CFD study'. Ne muodostavat yhdessä ainutlaatuisen sormenjäljen.

Siteeraa tätä