An Experimental study of diffuse ceiling ventilation with symmetrical and asymmetrical heat load distributions

  • Turku University of Applied Sciences

Tutkimustuotos: Artikkeli kirjassa/konferenssijulkaisussaConference article in proceedingsScientificvertaisarvioitu

67 Lataukset (Pure)

Abstrakti

Strength and location of heat loads have a significant effect on air distribution. Symmetrical and asymmetrical heat load distributions were studied at 40 W/floor-m2 (C40) and at 80 W/floor-m2 (C80) with diffuse ceiling ventilation. Experiments were carried out in a test chamber (5.5x3.8x3.2 m3, LxWxH) by conducting experiments with omnidirectional anemometers. In the symmetrical case (SC), cylindrical heat sources were located evenly on the floor. In the asymmetrical case (AC), double office layout including a seated-dummy with a laptop and a monitor was conducted next to warm window panels in the perimeter area. The results show that AC produces stronger circulating airflow pattern that SC from perimeter area to opposite corridor side, because heat load was equally distributed in SC. In AC, the air temperature was higher (0.5°C, 0.9°C) and the air speed was lower (0.02 m/s, 0.04 m/s) in the perimeter area than in the corridor side regarding the seated person zone at C40 and C80,
respectively. In SC, significant horizontal temperature difference was not obtained between the perimeter and corridor sides. Thermal environment is classified as the category B defined by the EN ISO 7730:2005 for common heat load conditions and category C for peak load conditions.
AlkuperäiskieliEnglanti
OtsikkoProceedings of Roomvent & Ventilation 2018, 2-5th of June 2018, Espoo, Finland
ToimittajatRisto Kosonen, Mervi Ahola, Jarkko Narvanne
KustantajaSIY Sisäilmatieto Oy
ISBN (elektroninen)978-952-5236-48-4
TilaJulkaistu - 5 kesäk. 2018
OKM-julkaisutyyppiA4 Artikkeli konferenssijulkaisussa
TapahtumaInternational Conference on Air Distribution in Rooms - Espoo, Suomi
Kesto: 2 kesäk. 20185 kesäk. 2018

Conference

ConferenceInternational Conference on Air Distribution in Rooms
LyhennettäROOMVENT
Maa/AlueSuomi
KaupunkiEspoo
Ajanjakso02/06/201805/06/2018

YK:n kestävän kehityksen tavoitteet

Tämä tuotos edistää seuraavia kestävän kehityksen tavoitteita:

  1. SDG 9 – Teollisuus, innovaatiot ja infrastruktuuri
    SDG 9 – Teollisuus, innovaatiot ja infrastruktuuri

Sormenjälki

Sukella tutkimusaiheisiin 'An Experimental study of diffuse ceiling ventilation with symmetrical and asymmetrical heat load distributions'. Ne muodostavat yhdessä ainutlaatuisen sormenjäljen.

Siteeraa tätä