Abstrakti
A back-EMF-based position observer for motion-sensorless synchronous reluctance motor drives is augmented with high-frequency signal-injection method for improved low-speed operation. Previously proposed observer structure is further improved to account for the cross saturation in the motor. The combined observer is experimentally evaluated using a 6.7kW synchronous reluctance motor drive in low-speed operation and under various load conditions. The resulting position error at low speeds and standstill is small.
Alkuperäiskieli | Englanti |
---|---|
Otsikko | IEEE International Electric Machines and Drives Conference (IEMDC) |
Julkaisupaikka | Chicago, IL, USA |
Sivut | 656-662 |
ISBN (elektroninen) | 978-1-4673-4973-4 |
DOI - pysyväislinkit | |
Tila | Julkaistu - 12 toukok. 2013 |
OKM-julkaisutyyppi | A4 Artikkeli konferenssijulkaisussa |
Tutkimusalat
- observer
- parameter uncertainties
- speed sensorless
- stability conditions