Abstrakti
Accurate dispensing methods reduces waste of products and ensures that the promised amount of a product is delivered. The accuracy of a flow meter, weight measurement of a container and time-based measurement is tested by pumping 100 g, 200 g and 300 g of liquid through a peristaltic pump and analyzing the deviations in mass from the desired amount. The fluids used for testing are liquid soap, water, conditioner, and hand sanitizer. Based on the results, it is concluded that weight measurement is the most accurate, and that the viscosity and chemical structure of the liquid affects the accuracy of the dispensing methods.
Alkuperäiskieli | Englanti |
---|---|
Otsikko | Proceedings of the 6th Baltic Mechatronics Symposium |
Kustantaja | AALTO-YLIOPISTO |
Sivumäärä | 6 |
ISBN (elektroninen) | 978-952-64-9605-4 |
Tila | Julkaistu - 27 huhtikuuta 2021 |
OKM-julkaisutyyppi | A4 Artikkeli konferenssijulkaisuussa |
Tapahtuma | Baltic Mechatronics Symposium - Virtual, Online Kesto: 27 huhtikuuta 2021 → 27 huhtikuuta 2021 Konferenssinumero: 6 |
Conference
Conference | Baltic Mechatronics Symposium |
---|---|
Kaupunki | Virtual, Online |
Ajanjakso | 27/04/2021 → 27/04/2021 |