Abstract
This paper presents the characterization of a resistive HVDC reference divider and methods to establish a traceability. The divider is designed for use as a laboratory reference for calibration of HVDC measuring systems up to 1000 kV. Targeting a measurement uncertainty of 20 ppm at full voltage has put a focus on the temperature coefficients of the resistors, elimination of humidity dependence and control of leakage currents in the high voltage arm.
| Original language | English |
|---|---|
| Title of host publication | CPEM 2014 - 29th Conference on Precision Electromagnetic Measurements, Digest |
| Publisher | IEEE |
| Pages | 780-781 |
| Number of pages | 2 |
| ISBN (Electronic) | 9781479952052 |
| DOIs | |
| Publication status | Published - 12 Sept 2014 |
| MoE publication type | A4 Conference publication |
| Event | Conference on Precision Electromagnetic Measurements - Rio de Janeiro, Brazil Duration: 24 Aug 2014 → 29 Aug 2014 Conference number: 29 |
Conference
| Conference | Conference on Precision Electromagnetic Measurements |
|---|---|
| Abbreviated title | CPEM |
| Country/Territory | Brazil |
| City | Rio de Janeiro |
| Period | 24/08/2014 → 29/08/2014 |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 7 Affordable and Clean Energy
Keywords
- High-voltage techniques
- HVDC transmission
- measurement techniques
- measurement uncertainty
- voltage measurement