Power quality assessment of energy efficient cooling systems in data centers

Arash Mousavi, Alireza Yavarian, Valeriy Vyatkin, Xiaojing Zhang

Research output: Chapter in Book/Report/Conference proceedingConference article in proceedingsScientificpeer-review

2 Citations (Scopus)

Abstract

Power quality is an important aspect in data centers and power system operators prefer data centers with high standard power quality. Modern data centers consume large amount of electrical power. As the cooling systems are accounted for 40% of the total power consumption in data centers, energy efficiency in this sector is of high importance. This research investigates if the existing energy efficient cooling strategies can also meet the power quality level defined by the IEEE 519-2014 standard. In this research three automation strategies based on IEC 61499 standard for cooling system in a typical server room are considered and the effects of each one on power quality parameters are investigated via simulation. The investigation has been performed for both; internal power grid of data center and upstream power network that data center is connected to. Power quality parameters which are considered are Total Harmonic Distortion (THD), voltage and current distortions. Results of simulation prove that the automation strategies with highest energy efficiency, also meet the higher power quality standard.

Original languageEnglish
Title of host publicationProceedings IECON 2017 - 43rd Annual Conference of the IEEE Industrial Electronics Society
PublisherIEEE
Pages7191-7196
Number of pages6
Volume2017-January
ISBN (Electronic)9781538611272
DOIs
Publication statusPublished - 15 Dec 2017
MoE publication typeA4 Conference publication
EventAnnual Conference of the IEEE Industrial Electronics Society - Beijing, China
Duration: 29 Oct 20171 Nov 2017
Conference number: 43
http://iecon2017.csp.escience.cn/

Publication series

Name Proceedings of the Annual Conference of the IEEE Industrial Electronics Society
PublisherIEEE
ISSN (Print)1553-572X

Conference

ConferenceAnnual Conference of the IEEE Industrial Electronics Society
Abbreviated titleIECON
Country/TerritoryChina
CityBeijing
Period29/10/201701/11/2017
Internet address

Keywords

  • automation
  • cooling systems
  • data center
  • efficiency
  • electrical model
  • IEC 61499 Function Block
  • power quality
  • thermal model
  • total harmonic distortion
  • voltage and current fluctuations

Fingerprint

Dive into the research topics of 'Power quality assessment of energy efficient cooling systems in data centers'. Together they form a unique fingerprint.

Cite this