Abstract
Model-based control techniques are frequently used with grid-connected converters. This paper proposes a method for identifying model parameters of an LCL filter connected to a grid converter for control purposes. In identification, a discrete-time autoregressive moving average with exogenous input (ARMAX) model structure is used and closed-loop current control is considered. The resulting discrete-time model parameters are translated into the continuous-time physical parameters (inductance and capacitance values of the filter) by comparing the estimated discrete-time model with the analytical discrete-time model. Simulation and experimental results show that the proposed method yields good parameter estimates that are suitable for control tuning.
Original language | English |
---|---|
Title of host publication | 9th International Conference on Power Electronics (ICPE 2015-ECCE Asia) |
Place of Publication | Seoul, South Korea |
Pages | 1260-1267 |
DOIs | |
Publication status | Published - 1 Jun 2015 |
MoE publication type | A4 Conference publication |
Keywords
- identification
- LCL filter
- physical parameters
- self commissioning