Experimental realization of a Coulomb blockade refrigerator

Research output: Contribution to journalArticleScientificpeer-review

Researchers

Research units

Abstract

We present an experimental realization of a Coulomb blockade refrigerator (CBR) based on a single-electron transistor (SET). In the present structure, the SET island is interrupted by a superconducting inclusion to permit charge transport while preventing heat flow. At certain values of the bias and gate voltages, the current through the SET cools one of the junctions. The measurements follow the theoretical model down to ∼80 mK, which was the base temperature of the current measurements. The observed cooling increases rapidly with decreasing temperature, in agreement with the theory, reaching about a 15 mK drop at the base temperature. The CBR appears as a promising electronic cooler at temperatures well below 100 mK.

Details

Original languageEnglish
Article number201407
Pages (from-to)1-5
Number of pages5
JournalPhysical Review B
Volume90
Issue number20
Publication statusPublished - 24 Nov 2014
MoE publication typeA1 Journal article-refereed

Download statistics

No data available

ID: 887990