In order to avoid machine downtime and loss of production, it is important to maintain adequate technical performance level of the fluid at all times. This is done by filtering, without which the fluid gets contaminated with harmful particles over time.
Comprehensive laboratory tests have been made in order to produce filtration performance data relating the effect of flow rate, contaminant particle concentration, and fluid temperature to the pressure drop measured over the filter element. This work demonstrates the mathematical correlation models derived from the experimental data.
Comprehensive laboratory tests have been made in order to produce filtration performance data relating the effect of flow rate, contaminant particle concentration, and fluid temperature to the pressure drop measured over the filter element. This work demonstrates the mathematical correlation models derived from the experimental data.
Original language | English |
---|---|
Title of host publication | Integrated Energy Solutions to Smart And Green Shipping |
Subtitle of host publication | 2019 Edition |
Editors | Zou Guangrong |
Place of Publication | Helsinki, Finland |
Publisher | VTT Technical Research Centre of Finland |
Chapter | 7 |
Pages | 45-50 |
Number of pages | 6 |
Edition | 2019 |
ISBN (Electronic) | 978-951-38-8688-2 |
ISBN (Print) | 978-951-38-8689-9 |
Publication status | Published - Jun 2019 |
MoE publication type | Not Eligible |
Publication series
Name | VTT Technology |
---|---|
Publisher | VTT |
Number | 354 |
ISSN (Print) | 2242-1211 |
ISSN (Electronic) | 2242-122X |
Keywords
- hydraulic fluid filter
- correlation model
- condition monitoring
Fingerprint
Dive into the research topics of 'Effects of flow and oil properties on filter service life'. Together they form a unique fingerprint.Projects
- 1 Finished
-
INTENS: Integrated Energy Solutions to Green Shipping
Pietola, M. (Principal investigator)
01/01/2018 → 30/06/2021
Project: Business Finland: Other research funding