Accuracy and precision of navigated transcranial magnetic stimulation

Aino E. Nieminen, Jaakko O. Nieminen*, Matti Stenroos, Pavel Novikov, Maria Nazarova, Selja Vaalto, Vadim Nikulin, Risto J. Ilmoniemi

*Corresponding author for this work

Research output: Contribution to journalArticleScientificpeer-review

20 Citations (Scopus)
128 Downloads (Pure)

Abstract

Objective. Transcranial magnetic stimulation (TMS) induces an electric field (E-field) in the cortex. To facilitate stimulation targeting, image-guided neuronavigation systems have been introduced. Such systems track the placement of the coil with respect to the head and visualize the estimated cortical stimulation location on an anatomical brain image in real time. The accuracy and precision of the neuronavigation is affected by multiple factors. Our aim was to analyze how different factors in TMS neuronavigation affect the accuracy and precision of the coil-head coregistration and the estimated E-field. Approach. By performing simulations, we estimated navigation errors due to distortions in magnetic resonance images (MRIs), head-to-MRI registration (landmark- and surface-based registrations), localization and movement of the head tracker, and localization of the coil tracker. We analyzed the effect of these errors on coil and head coregistration and on the induced E-field as determined with simplistic and realistic head models. Main results. Average total coregistration accuracies were in the range of 2.2-3.6 mm and 1°; precision values were about half of the accuracy values. The coregistration errors were mainly due to head-to-MRI registration with average accuracies 1.5-1.9 mm/0.2-0.4° and precisions 0.5-0.8 mm/0.1-0.2° better with surface-based registration. The other major source of error was the movement of the head tracker with average accuracy of 1.5 mm and precision of 1.1 mm. When assessed within an E-field method, the average accuracies of the peak E-field location, orientation, and magnitude ranged between 1.5 and 5.0 mm, 0.9 and 4.8°, and 4.4 and 8.5% across the E-field models studied. The largest errors were obtained with the landmark-based registration. When computing another accuracy measure with the most realistic E-field model as a reference, the accuracies tended to improve from about 10 mm/15°/25% to about 2 mm/2°/5% when increasing realism of the E-field model. Significance. The results of this comprehensive analysis help TMS operators to recognize the main sources of error in TMS navigation and that the coregistration errors and their effect in the E-field estimation depend on the methods applied. To ensure reliable TMS navigation, we recommend surface-based head-to-MRI registration and realistic models for E-field computations.

Original languageEnglish
Article number066037
Pages (from-to)1-17
Number of pages17
JournalJOURNAL OF NEURAL ENGINEERING
Volume19
Issue number6
DOIs
Publication statusPublished - 1 Dec 2022
MoE publication typeA1 Journal article-refereed

Keywords

  • accuracy
  • coregistration
  • neuronavigation
  • precision
  • TMS
  • transcranial magnetic stimulation

Fingerprint

Dive into the research topics of 'Accuracy and precision of navigated transcranial magnetic stimulation'. Together they form a unique fingerprint.

Cite this