Skip to main navigation Skip to search Skip to main content

A virtual anti-scatter grid for multi-energy photon counting detector systems

  • Zenith Purisha*
  • , Alexander Winkler*
  • , Muhammad Emzir
  • , Roland Hostettler
  • , Panja Luukka
  • , Simo Särkkä
  • *Corresponding author for this work
  • Gadjah Mada University
  • Helsinki Institute of Physics
  • Detection Technology Oyj
  • King Fahd University of Petroleum and Minerals
  • Uppsala University

Research output: Contribution to journal › Article › Scientific › peer-review

18 Downloads (Pure)

Abstract

Photon-counting (PC) systems are the next technological generation of medical computed tomography (CT) imaging and is being worked on by all major system providers. CT devices that are based on PC detectors enable multi-energy data collection. The information-content of this data can be used to obtain more detailed patient data, which improves the quality of reconstructions, compared to conventional detector systems. However, PC CT systems are subject to radiation scatter as just as any other imaging systems is. Conventionally anti-scatter grids (ASG) are used to reduce the scatter effect. These are however an imperfect solution, especially for PC detectors. In this work, a software-based scatter correction method, thus a virtual ASG is proposed. The method is tailoring a new statistical model in the measurement space and combining it with the statistical inversion method called Markov chain Monte Carlo (MCMC). The method can recover the measurement data from dense projections. We present the method on simulated data of a single photon emission computed tomography (SPECT) problem for which only under-sampled data is available. However, our approach can in principle be generalised to CT, PC-CT, Positron emission tomography (PET), radiotherapy, or even digital radiography problems. The results show that the proposed model performs similarly as physical ASGs and for cases where ASGs are not possible. The model further offers a significant improvement in the quality of the reconstruction image compared to the image reconstruction from original under-sampled data.

Original languageEnglish
Article number105287
Number of pages14
JournalPhysica Scripta
Volume99
Issue number10
DOIs
Publication statusPublished - 1 Oct 2024
MoE publication typeA1 Journal article-refereed

Keywords

  • anti-scatter
  • counting
  • grids
  • multi-energy
  • photon
  • virtual

Fingerprint

Dive into the research topics of 'A virtual anti-scatter grid for multi-energy photon counting detector systems'. Together they form a unique fingerprint.
  • Multispectral photon-counting for medical imaging and beam characterization

    Särkkä, S. (Principal investigator), Purisha, Z. (Project Member), Gao, R. (Project Member), Tronarp, F. (Project Member), Yamin, A. (Project Member), Hassan, S. S. (Project Member), Zhao, Z. (Project Member), Emzir, M. (Project Member) & Sarmavuori, J. (Project Member)

    01/01/2018 → 31/12/2021

    Project: Academy of Finland: Other research funding

  • Probabilistic Deep Learning via Hierarchical Stochastic Partial Differential Equations

    Särkkä, S. (Principal investigator), Gao, R. (Project Member), Hostettler, R. (Project Member), Karvonen, T. (Project Member), Sarmavuori, J. (Project Member), Purisha, Z. (Project Member), Bahrami Rad, A. (Project Member), Raitoharju, M. (Project Member), Emzir, M. (Project Member) & Tronarp, F. (Project Member)

    01/01/2018 → 31/12/2019

    Project: Academy of Finland: Other research funding

Cite this