Abstract
Local thermal comfort and draught rate has been studied widely. There has been more meaningful research performed in controlled boundary condition situations than in actual work environments involving occupants. Thermal comfort conditions in office buildings in Estonia have been barely investigated in the past. In this paper, the results of thermal comfort and draught rate assessment in five office buildings in Tallinn are presented and discussed. Studied office landscapes vary in heating, ventilation and cooling system parameters, room units, and elements. All sample buildings were less than six years old, equipped with dedicated outdoor air ventilation system and room conditioning units. The on-site measurements consisted of thermal comfort and draught rate assessment with indoor climate questionnaire. The purpose of the survey is to assess the correspondence between heating, ventilation and cooling system design, and the actual situation. Results show, whether and in what extent the standard-based criteria for thermal comfort is suitable for actual usage of the occupants. Preferring one room conditioning unit type or system may not guarantee better thermal environment without draught. Although some heating, ventilation and cooling systems observed in this study should create the prerequisites for ensuring more comfort, results show that this is not the case for all buildings in this study.
| Original language | English |
|---|---|
| Article number | 127 |
| Number of pages | 21 |
| Journal | Atmosphere |
| Volume | 11 |
| Issue number | 2 |
| DOIs | |
| Publication status | Published - 1 Feb 2020 |
| MoE publication type | A1 Journal article-refereed |
Funding
This research was supported by the Estonian Centre of Excellence in Zero Energy and Resource Effcient Smart Buildings and Districts, ZEBE (grant 2014-2020.4.01.15-0016) funded by the European Regional Development Fund, by the programme Mobilitas Pluss (Grant No-2014-2020.4.01.16-0024, MOBTP88), by the European Commission through the H2020 project Finest Twins (grant No. 856602) and the Estonian Research Council grant (PSG409). The authors are grateful for the provided cooperation of the building owners, questionnaire respondents for their time and the valuable help from Tallinn University of Technology graduate students.
Keywords
- Cooling period
- Draught
- Open office
- Thermal comfort
Fingerprint
Dive into the research topics of 'A comparative study on cooling period thermal comfort assessment in modern open office landscape in Estonia'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver